  • 9155-MNT119

    Calibration system mounting adaptor for Endevco 7270A/7280A family single axis accelerometers. Used on ¼-28 and 10-32 UNF threaded shakers.

    Publié le 


  • 9155-MNT118

    Calibration system mounting adaptor for Endevco 7274A/7284A triaxial accelerometers. Used on ¼-28 and 10-32 UNF threaded shakers.

    Publié le 


  • 9155-MNT117

    Calibration system mounting adaptor for PCB 350B4x triaxial accelerometers. Used on ¼-28 and 10-32 UNF threaded shakers.

    Publié le 


  • 9155-MNT113

    Calibration system mounting adaptor for 9155D-875 high payload shaker (year 2024 and later). Includes reference accelerometer, no signal conditioner.

    Publié le 


  • 9155D-USC-100

    Universal Signal Conditioning option for 9155 calibration system for Piezoresistive, Variable Capacitance, Bridge, Charge, ICP SUT types. Computer controlled conditioner with measurement selection hardware integrated in 19 equipment rack mount sy

    Publié le 


  • 9155D-Laptop

    9155 Windows laptop PC with MS Office installed

    Publié le 


  • 9155D-CUSC

    Calibration service for TMS Model 9155D-USC Signal Conditioner. NIST traceable and A2LA accredited.

    Publié le 


  • 9155D-C919-1/4

    Reference Calibration Service for TMS Model 9919C. Calibration 1/4 inch 9919 reference microphone top with paired signal conditioner. 20 Hz to 20 kHz Frequency Range. Requires return of complete top reference fixture. Includes data on disk. A2LA accr

    Publié le 


  • 9155D-C919-1/2

    Reference Calibration Service for TMS Model 9919C. Calibration 1/2 inch 9919 reference microphone top with paired signal conditioner. 20 Hz to 20 kHz Frequency Range. Requires return of complete top reference fixture. Includes data on disk. A2LA accr

    Publié le 


  • 9155D-C6251

    Calibration service for NI 6251 PCI DAQ card. A2LA or equivalent 17025 accreditation

    Publié le 


  • 9155D-C427

    Calibration service for TMS Model 9155D-427.  Calibration of PCB 482C27 ICP® Sensor Signal Conditioner and 422 series In-line Charge Amplifier. A2LA accredited.

    Publié le 


  • 9155D-C405

    Calibration service for TMS Model 9155D-405.  Calibration of PCB 482C05 ICP® Sensor Signal Conditioner and 422 series In-line Charge Amplifier. A2LA accredited.

    Publié le 


  • 9155D-C301P

    Reference standard calibration service for TMS Model 9155 systems including a 301A10 or 301A11 reference standard. Calibration is performed by a primary method using laser interferometry. Includes Data on disk. A2LA accredited.

    Publié le 


  • 9155D-C301-LF

    Low frequency reference standard calibration service. Calibration of PCB 301 style reference accelerometer system from 0.5 Hz to 10 Hz by optical encoder. Includes Data on disk. A2LA certified. Requires calibration service 9155D-C301.

    Publié le 


  • 9155D-917

    Acoustic Microphone Option for Model 9155 Calibration System. Calibrates from 31.4 Hz to 10kHz with Model 9917C and ICP Reference Microphone. Includes 9155D-910 software option.

    Publié le 


  • 9155D-910

    Software Only Option For Acoustic Microphone Support. IEC 61094-5 Comparison Method With Acoustic Field Correction (Free Field, Random Incidence)

    Publié le